Class PC Level ATS Automatic Transfer Switch Dual Power 400V 630A 4P

Brand Name : Fenigal/OEM

Model Number : FMPC

Certification : CE,CCC

Place of Origin : China

MOQ : 1 unit

Price : Negotiate

Payment Terms : T/T, Western Union

Supply Ability : 10,000pcs/month

Delivery Time : 5-8 working days bulk order negotiate

Packaging Details : Standard export carton

Max. current : 100A

Max. voltage : 400V

Pole : 2P,3P,4P

Rated voltage : 230V/400V

Rated current : 16A 20A 25A 32A 40A 50A 63A 80A 100A

Product name : Dual Power Automatic Transfer Switch ATS

Color : white

Frequency : AC 50 Hz/60Hz

Operation type : Manual Operation,Auto&Manual

Standard : IEC60947-6-1

Contact Now

Class PC level dual power automatic transfer switch 400V 630A 4P

1.The dual-power automatic transfer switch (ATS) is a newly developed miniature household power transfer switch, is mainly used to test whether the main power or reserve power is normal.

When the normal power supply is abnormal, the reserve power supply will start work immediately to ensure continuity, reliability and safety of the power supply. It is specially designed for household rail installation for PZ30 distribution box.

2.The ATS is suitable for emergency power supply systems of AC50 or 60Hz and rated voltage 400V. It is featured with firm structure, reliable transfer, easy installation and maintenance, and long life, is widely used in places where frequent power outage is not allowed. Both electric and operation and manual operation are available. The ATS is composed of TES and controller.

3.According to the standard GB/T14048.11 Part 6-1: Multiple function equipment - Transfer switching equipment, we can know that ATS is the most suitable low-voltage switchgear and control device.

Model
Rated current(lth) 250
Rated working current(le) 125A,160A,200A,225A,250A
Rated insulation voltage(Ui) 690V
Rated concussion withstand voltage(Uimp) 8Kv
Rated working voltage(Ue) AV400V
Using classes AC-33B
Rated limited shortcircuit current 17KA
Rated short-time withstand current 10kA/30ms
Transfer Ⅰ——Ⅱor Ⅱ——Ⅰ 0.6s
Control power voltage DC24V,80V,110V,AC220V
Rated frequency Start 325W
Normal 62W
Weight(kg)4 pole 6.0(125A);7.6
Name Content
Enterprise code Shanghai Yuhuang electric co.,ltd
Product category PC class Automatic Transfer Switch
Design code 1
Current rank NA/N/C:32A,125A,250A,400A,630ASA/S/LA/L:125A,250A,630AG:100A,250A,630A,1600A,3200AM:1600A AQ:3200A
Product code NA:16A~630A(Integral type,two positions)N:16A~630A(Split type,two positions)C:16A~630A(Split type,two positions)M:630A~1600A(Split type,two positions)Q:630A~3200A(Split type,two positions)SA:20A~630A(Integral type,Three positions)S:20A~630A( Split type,Three positions)LA:20A~630A(Integral type,Two positions)L:20A~630A(Split type,two positions)G:GA:16A~3200A(With fire protection function)GA1:16A~100A(Without fire protection function)
Pole 2P(125A and below 125A products),3P,4P
Rated current 16A~3200A
Working mode R=Self-input and self-recoverS=Self-input without self-recoverF=Utility-Generator

Normal running time and installation conditions

1.Ambient air temperature

Temperature should be within -5℃~40℃, and the average temperature within 24h should not exceed 35℃.

2.Altitude

Altitude of the installation site should not exceed 2000m.

3.Atmospheric conditions

The relative humidity of the installation site should not exceed 50% at maximum temperature 40℃, and it will be higher at minimum temperature -5℃, for instance, 90% at +20℃. Please take measures for the dew on product surface caused by temperature change.

4.Class of pollution

Pollution class of ATS meets the specified level of GB/T14048.11.

5.Installation category

Installation category of ATS meets the specified category in GB/T14048.11

Matterts need attention

1.Manual/automatic operation

ATS with automatic operation can ensure power generation and power-off performances, but for ATS with manual operation , it cannot ensure the above performance due to the speed of power generation and power-off or operator differences. Excessive silver alloy loss may occur during manual power generation and power down. Therefore, set the selector switch at the manual position under normal condition, and pull it to the manual position when all power is turned off to check and maintain the operating system and contacts. After the manual operation is completed pull the selector back to the automatic position.

2.Control circuit

ATS will be active in an instant. After the conversion is complete, the coils in the control circuit are disconnected by the internal converter. The coil can operate normally with a rated voltage of 80%~110%, and too low voltage may cause the coil to heat up or even ignite.

Class PC Level ATS Automatic Transfer Switch Dual Power 400V 630A 4P

Class PC Level ATS Automatic Transfer Switch Dual Power 400V 630A 4P

Class PC Level ATS Automatic Transfer Switch Dual Power 400V 630A 4P


Product Tags:

Class PC ATS Automatic Transfer Switch

      

400V Automatic Transfer Switch

      

630A 4P Automatic Transfer Switch

      
Quality Class PC Level ATS Automatic Transfer Switch Dual Power 400V 630A 4P for sale

Class PC Level ATS Automatic Transfer Switch Dual Power 400V 630A 4P Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuxi Fenigal Science & Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)